Drilled Pier Frost Heave | Eng-Tips
Feb 11, 2025 · Hello, I am currently designing concrete drilled piers, and per the geotech report, the recommendations incur a 1600 psf design stress for potential frost heave. The recommendations …
Frost Depth | Eng-Tips
Oct 1, 2025 · Frost depth also tends to presume a bit of "heated building" in the tabulated numbers, so keep that in mind for say, a freezer building, unheated storage, etc.
Sources for Frost Depth Values | Eng-Tips
Mar 1, 2022 · Hello all, this is my first post here so please bear with me. Where do you go to find accurate frost depth/line values? At my job, we often have to design footers/foundations rapidly so as …
Which soils are most susceptible to frost heaving? | Eng-Tips
Feb 17, 2007 · However there is still some potential for frost heave, especially of there are variations in the soil. As mentioned in the other thread, would be best to insulate footings having inadequate …
Frost depth consideration in existing rock layer | Eng-Tips
Feb 2, 2004 · If I propose to install a strip footing of reinf. concrete for live and dead loads such that design allowable soil bearing capacity is 8000 psf ...do i have to be concerned about the fact that the …
Retaining Wall Frost Protection | Eng-Tips
Feb 24, 2009 · I am looking to see if there are any requirements for providing frost protection for isolated retaining walls. I can only find requirements in the IBC for foundations and footings however, I’m not …
Frost Protection for Interior Footings | Eng-Tips
Nov 18, 2024 · If the building is heated there is no need to frost protect interior footings. On the other hand, if the structure is an unheated warehouse, then they should be protected just as exterior …
Frost line consideration for walkout basement | Eng-Tips
Oct 21, 2024 · Hello, What is your opinion regarding the bottom of new foundation for the basement walkout stair? Creating a walkout for the basement will affect the frost line. Should I start counting …
Frost depth for turndown slab | Eng-Tips
Jul 30, 2010 · I have virtually an unheated metal shack. It will sit on a slab on grade with a turndown. Is is necessary for the turndown to bear below the frost depth? In my mind, only unheated bearing …
Can foundation weight allow avoidance of frost depth? | Eng-Tips
Mar 3, 2011 · A contractor is suggesting the use of 1ft deep, very wide concrete slab to support heavy rotating equipment. The local jurisdiction has a required frost depth 42in. Can a very heavy …